CEILING FANS - SUMMER FANS

183 TDA Highstream 800 A B Product Code-No. Amp. (max.) A B C ETW 1.0 892032 1.0 84 160 88 ETW 1.5 892021 1.5 115 205 100 ETW 2.2 892022 2.2 115 205 100 ETW 3.5 892033 3.5 170 255 140 ETW 5.0 892018 5.0 170 255 140 ETW 7.5 892019 7.5 100 305 140 ETW 10.0 892038 10.0 300 325 185 FB-Delta-T TDA-Highstream The TDA-Highstream 600 and 800 models were specially developed for areas that require protection against contact. These units feature lower energy consumption with top air flow and maximum range. Suspended on chains (supplied), they can reach floor level even at great heights with a high ∆T. The maximum speed limit on the TDA-Control unit prevents drafts. And neither damp nor dirt are a problem: models in the TDA-Highstream range are resistant to both, with protection class IP44. Product Code No. Power (W) Air delivery (m³/h) Dim. A (mm) Dim. B (mm) Weight (kg) Vertical Range (m) TDA-HS 600 9306080 123 13,000 680 270 10.9 11 TDA-HS 800 9307580 123 15,650 830 270 13.8 16 Dimensions mm FB-Delta-T remote control The FB-Delta-T remote control was developed for small rooms with high ceilings, which have an area of up to 100 m² and only require one ceiling fan. The advantage to this is that floor and ceiling sensors do not have to be wired in. The ceiling sensor is located in the fan controls on the ceiling, and the floor sensor is integrated into the aluminium rating plate on the handheld transmitter. In addition to four-level manual fan controls, a timer control up to 99 minutes and an automatic summer mode with preselected target temperature, the Delta-T range also offers fully-fledged automatic temperature balancing in the winter. Communication between the two temperature sensors and the electronic controls in the fan head is by radio (434 Mhz). The fan starts at a low level when a ∆T of 2 °K is measured. With every further increase of 2 °K, it switches to the next level. When the ∆T is less than 2 °K, the fan automatically switches off. The maximum fan output is 100 W. The FB-Delta-T is suitable for all our alternating current ceiling fans. Product Code No. Function Motor FB-DELTA-T 85396 4 speeds/OFF receiver downrod canopy Unlike TDA fans, units in the TDA-Highstream series also allow for installation with targeted airflow. Installed diagonally on chains, the air is directed horizontally or diagonally. This allows heat layers to be used that normal TDA fans cannot recircuBuilt-in areas, e.g. warehouse office TDA 1400 I TDA 1400 I TDA-HS 800 late to the occupied areas of the room. To prevent drafts, an ETW 1.0 #892032 intermediate transformer should be planned between the TDA-Control and TDA-Highstream. The appropriate operating level is chosen by the fitter. 5-speed transformers for hum free control of several ceiling fans. Industrial housing, colour light grey RAL 7035, protection class IP54, (0-80-110-140-170/190-230 V), control lamp, max. ambient temperature 35° C. ETW: 5-speed transformers for hum free control of one or several ceiling fans (up to 30 units with ETW 10.0). 230 Vac 230 Vac B A C

RkJQdWJsaXNoZXIy NjQyNzA=