Industrial & Urban lightting

17 Intro CLF UPS OK - DC + DC N L INPUT: 190/305VAC 50/60Hz 186/275VDC EXAMPLE OF POWER AND SYSTEM SIZING THE SIZING OF THE ELECTRICAL SYSTEM SHOULD BE MADE CONSIDERING THE FINAL POWER OF THE LED FIXTURES. THEREFORE, THERE WILL BE NO DIFFERENCE BETWEEN A SYSTEM WITH STANDARD LAMPS (ON/OFF WITHOUT CLF) AND ONE WITH LAMPS FEATURING CLF TECHNOLOGY. THE CLF SYSTEM CAN BE DISABLED AT ANY TIME USING SOFTWARE, IMMEDIATELY RESTORING THE FULL POWER OF THE LAMP. IT FOLLOWS THAT, WITH CLF INSTALLED, THE FINAL POWER NEVER EXCEEDS THE NOMINAL POWER OF THE LAMP. IN FACT, THE LED LIGHT FIXTURE IS NEVER OVER-POWERED, GUARANTEEING A LONG LIFE. COMPATIBLE FIXTURES IN DIRECT CURRENT ALL OUR LIGHT FIXTURES WITH POWER EQUAL TO OR GREATER THAN 100W AC WORK BOTH IN ALTERNATING CURRENT (190/305VAC 50/60HZ) AND DIRECT CURRENT (186/275VDC), THEREFORE, THEY LEND THEMSELVES WELL FOR USE AS EMERGENCY LIGHTING IN COMPLIANCE WITH THE PREVAILING STANDARDS. TECHNICAL CHARACTERISTICS STANDARD FIXTURE ON/OFF FLAMP WITHOUTCLF FIXTURE FLAMP WITH CLF INITIAL POWER 200W AC 180W AC FINAL POWER 200W AC 200W AC LUMINOUS FLOW INITIAL NOMINAL (natural white LED) 29205 LM ~26451 LM LUMINOUS FLOW NOMINAL AFTER 90,000 HOURS 26285 LM ~26451 LM

RkJQdWJsaXNoZXIy NjQyNzA=